Testing Laboratory is equipped with following equipments: | ||
1 | Electronic Thickness Gauge | To Measure Zinc coating at any point in microns |
2 | Preece Test | Copper Sulphate solution test for uniformity of zinc coating |
3 | Stripping Test | Mass of Zinc coating in Grams/m2 with electronic weight scale |
4 | Hammer test & Knife Test | Adhesion of zinc coating with standard hammer & knife |
5 | Chemical Balance | Digital 0-3 Kg Contech make. |
6 | Weighing Platform Scale | 0-1 Tonne capacity Contech Make. |
7 | Facilities for Testing (Internal Parameters) | Acid Strength with hydrometer burette & pipette Iron Content in pickling & pre-flux tank etc. |
Flux Regeneration Unit | 1 set of FRU to monitor & Filter flux Continuously & automatically with set Parameters | |
Effluent Treatment Plant | ||
Sr. No. | Description | Quantity |
1 | Collection Tank | 1 No. |
2 | Reaction Tank with caustic & Lime addition by air agitation | 2 Nos. |
3 | Settling Tank | 1 Nos. |
4 | Sand Bed for collecting Solid wastes (Lime Sludge) | 2 Nos. |
Air Pollution Equipments | ||
As per the MPCB guidelines Galvanizing & Acid baths are fitted with Fugitive Emission suction system connected to scrubber system with water jet & discharge through chimney. Our commitment is not only to keep worker friendly environment but also to maintain pollution free surroundings. |
||
Finished Products | ||
Galvanized products include:
|
||
Manpower | Total manpower deployed is about 100 persons. |